Transformer Testing Categories
Transformer Testing
Showing 1–15 of 25 results
-
Electrical, Transformer Testing, Winding Resistance
Accessories for micro-ohmmeters
These accessories are used with micro-ohmmeters to ensure high-quality contact between the measurement probes and the object to be measured. They cover the whole range of applications by proposing sets of 2 x 1A and 10A pivoting or non-pivoting double test probes and Kelvin clamps or mini-clamps.
SKU: n/a -
Electrical, Transformer Oil Testing, Transformer Testing
BA100 Breakdown Analyzer test set
Breakdown Analyzer test set BA100 is the smallest and lightest portable oil test set of its rating evaluating the condition of the transformer insulating fluids. It is a necessary device that helps you to decide whether the transformer oil has to be changed in order to extend the asset life.
SKU: n/a -
Electrical, Transformer Oil Testing, Transformer Testing
BA75 Breakdown Analyzer test set
Breakdown Analyzer test set BA75 is the smallest and lightest portable oil test set of its rating evaluating the condition of the transformer insulating fluids. It is a necessary device that helps you to decide whether the transformer oil has to be changed in order to extend the asset life.
SKU: n/a -
Electrical, Transformer Oil Testing
BA80 Breakdown Analyzer test set
Breakdown Analyzer test set BA80 is the smallest and lightest portable oil test set of its rating evaluating the condition of the transformer insulating fluids. It is a necessary device that helps you to decide whether the transformer oil has to be changed in order to extend the asset life.
SKU: n/a -
Electrical, Transformer Testing, Winding Resistance
C.A 6240
Rugged and leakproof, the C.A 6240 is a top-of-the-range product designed for on-site, workshop or laboratory use.
It is ergonomic, lightweight and compact.Its wide LCD screen comprising 2 digital displays is particularly easy to read. It includes indications intended to facilitate implementation and interpretation of the measurements. The automatic measurement mode allows measurement to be triggered without pressing a button.
An automatic recording mode is also available.SKU: n/a -
Electrical, Transformer Testing, Winding Resistance
C.A 6255
An easy-to-use, high-performance instrument, the C.A 6255 micro-ohmmeter tests the quality of connections with precision (resolution of 0.1 µΩ) through the use of low resistance measurements.
-
4-wire measurement method, 1 µΩ to 2,500 Ω (7 ranges, 3 with a 10 A current)
automatic compensation of stray voltages at input terminals
3 measurement modes available depending on the application: inductive, non-inductive and non-inductive with automatic trigger
temperature compensation function for comparative results
programmable alarms / 1,500-measurement storage capacity
large backlit LCD display offering a wide range of symbols and indicators
50 V CAT III
Power supply: NiMH rechargeable battery
Dimensions: 270 x 250 x 180 mm; weight: 4 kg
SKU: n/a -
4-wire measurement method, 1 µΩ to 2,500 Ω (7 ranges, 3 with a 10 A current)
-
Electrical, Transformer Testing, Winding Resistance
C.A 6292
The C.A 6292 is supplied in a site-proof casing with clearly-identified connection terminalsto limit the risk of errors while also allowing quick connection of yourmeasurement leads.
The measurement results are displayedinstantaneously on the LCD screen, which is backlit for easy reading. The C.A 6292 can be configuredusing the rotary knob on the instrument or via a PC with the USB link.
The C.A 6292 can be used to measure in total safetyfor both people and equipment. The BSGmethod allows you to maintain theearthing on both sides of the object tested in order to remove any risk due toelectromagnetic induction phenomena. In this mode, the optional MR 6292 clampcan be used for current measurements up to 50 ADC.
The C.A 6292 can store in memory up to 8,000 measurement results.
SKU: n/a -
Electrical, Transformer Testing, Turns Ratio Testing
DTR 8510
Digital ratiometer for transformers
The DTR 8510 is a portable digital ratiometer for testing power, voltage and current transformers.
When connected to an uncoupled transformer, the DTR 8510 accurately measures the primary-to-secondary transformation ratio, while also indicating the polarity and excitation current.
The DTR 8510 is totally automatic and uses a test method which complies with the ANSI/IEEE standard. Users are not required to perform any calibration or balancing.
SKU: n/a -
All Products, Turns Ratio Testing
DTR 8510
Digital ratiometer for transformers
The DTR 8510 is a portable digital ratiometer for testing power, voltage and current transformers.
When connected to an uncoupled transformer, the DTR 8510 accurately measures the primary-to-secondary transformation ratio, while also indicating the polarity and excitation current.
The DTR 8510 is totally automatic and uses a test method which complies with the ANSI/IEEE standard. Users are not required to perform any calibration or balancing.
During each measurement, the DTR 8510 self-calibrates automatically and checks:
- Open circuits, windings, connections and cut-off circuits,
- Short-circuits (excessive value of excitation current),
- Incorrect connection of the test cables,
- Polarity reversals.
The measurements are displayed quickly and accurately.
Sales literature
User’s manual
SKU: n/a -
Electrical, Transformer Testing, Winding Resistance
MUX-R
MUX R Multiplexer for Transformer Testing: 100 Amps, 3 Channels, Demagnetization and Discharge
Raytech’s MUX R multiplexer is designed to drastically reduce cabling time and increase test performance.
It is made to be used with Raytech’s winding resistance and turns ratio meters. Any MUX R configuration can be easily controlled by a winding resistance meter’s touch panel or by remote control.
SKU: n/a -
-
Electrical, Transformer Testing, Turns Ratio Testing
T-Rex R
The T-Rex R is the same instrument as the T-Rex, but built into a 19″ rack housing.
Therefore, it can be used very well in test labs or be assembled into complete measurement systems. The T-Rex R three phase voltage extension is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-Mark III). The T-Rex R was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
SKU: n/a -
Electrical, Transformer Testing, Turns Ratio Testing
TR-1
The TR-1 turns ratio meter was designed to be a rugged and reliable automatic transformer ratio meter for accurate readings with on-site laboratory precision.
This system will test ratios to 4000:1. The design of this test system is based upon the popular Raytech Automatic Three Phase test set: TR-Mark III.
There is no maintenance required. There is no calibration procedure (No potentiometers to turn), due to the utilization of high precision components in the design.
Advanced Protection: Upon powering on, the system initializes itself with a self-calibrating, circuit checking sequence. If any problems are detected during this initialization period, or during operation, the operator is immediately notified. The system constantly monitors the condition of the transformer under test. The TR-1 can even recognize shorted leads and will terminate the test without any damage to the test equipment.
SKU: n/a -
Electrical, Transformer Testing, Turns Ratio Testing
TR-1P
The TR-1P single phase turns ratio meter is the same instrument as the TR-1 but with a built-in printer, which allows you to print out your measurement results directly in the field.
The TR-1P was designed to be a rugged and reliable automatic transformer ratio meter for accurate readings with on-site laboratory precision. This system will test ratios to 4000:1. The design of this test system is based upon the popular Raytech Automatic Three Phase test set: TR-Mark III.
There is no maintenance required. There is no calibration procedure (No potentiometers to turn), due to the utilization of high precision components in the design.
Advanced Protection: Upon powering on, the system initializes itself with a self-calibrating, circuit checking sequence. If any problems are detected during this initialization period, or during operation, the operator is immediately notified. The system constantly monitors the condition of the transformer under test. The TR-1P can even recognize shorted leads and will terminate the test without any damage to the test equipment.
SKU: n/a